Elemental Analysis
Depending on the requirements profile of your measurement tasks, we will work with you to find the optimum instrument solution for your laboratory, from classical spectrometry to the analysis of carbon, nitrogen, sulfur, and chlorine.
From routine analysis of few elements with moderate sample quantities to high-throughput multi-element analysis to dedicated mercury analysis, Analytik Jena offers optimized systems for atomic absorption (AAS) and atomic fluorescence spectrometry (AFS) as well as inductively coupled plasma systems for optical emission (ICP-OES ) and mass spectrometry (ICP-MS). For the determination of carbon, nitrogen, sulfur and chlorine, application-optimized elemental analysis systems (O-EA) are available for various matrices.
Product Details
Autosampler for high sample throughput and routine overnight operation
The AS-F and AS-FD autosamplers for flame and hydride technologies and AS-GF for graphite furnace use provide unique flexibility and efficiency in routine analysis. In addition to standard functions, the autosamplers provide automatic sample feed and standard preparation, intelligent sample dilution and concentration, automated dosage of modifiers and automatic depth adjustment. Combined with high dosage accuracy and intelligent cleaning control when concentrations are exceeded, they make unattended operations (even overnight) a matter of routine and ensure smooth processes and high sample throughputs. Sample preparation is reduced to a minimum, improving the cost per sample and your profitability.
Accessories for ICP-OES and ICP-MS
Customized sample introduction kits
Matrix-optimized sample introduction kits guarantee optimal adaptation of the instrument to your application and ensure reliable results and easy handling.
Sample introduction kits for ICP-OES
- Standard Kit recommended for the sample introduction of aqueous samples
- Organic Kit recommended for the sample introduction of petrochemical samples and organic solvents
- Salt Kit recommended for the sample introduction of aqueous samples with high salt contents
- HF Kit recommended for the sample introduction of samples containing hydrofluoric acid (HF), e.g. in refractory metals, rare earth and mineralogical applications
Sample introduction kits for ICP-MS
- Standard Kit recommended for the sample introduction of aqueous samples with moderate acid concentration (<10 % HNO3 or HCl)
- Organic Kit recommended for the sample introduction of organic solvents and other organic matrices
- Geochem Kit made from corrosion resistant PFA material, incl. Sapphire injector for the semi-demountable torch, recommended for the sample introduction of aqueous samples containing corrosive acids like HF, H2SO4, H3PO4, HCl4
- Inert Semicon Kit made from corrosion resistant PFA material, incl. platinum injector for the semi-demountable torch, recommended for trace element analysis in aqueous samples containing corrosive acids like HF, H2SO4, H3PO4, HCl4